Energy ABC: geothermal
Economy & innovation — di Lorenzo Brenna
Geothermal and mini-geothermal: the term derives from Greek. Geothermal refers to energy generated by means of geological heat sources.

Geothermal and mini-geothermal: the term derives from Greek. Geothermal refers to energy generated by means of geological heat sources.
Geothermal energy is based on the natural heat production of the
Earth (geothermy), fed by three components:
– Primordial thermal energy coming from the Earth's core.
Our planet can be divided into three macro-zones: the
central core, where matter exists in a molten state; the
mantle; and the surface layer, i.e. the Earth's crust. Heat
tends to rise towards the surface through convective motion,
feeding the geological phenomenon of plate tectonics. Volcanoes,
geysers, fumaroles and thermal springs are some of the manifestations of
this heat.
– Thermal energy released in nuclear decay processes of
radioactive elements naturally contained within the Earth,
such as uranium and thorium, which tend to transform into lead, and
potassium, whose decay leads to the formation of argon and
lime.
– Thermal energy coming from solar radiation and reflected
from the Earth's surface towards the atmosphere in the form of
heat.
Geothermy consists of channelling steam from underground
water sources towards dedicated turbines used for
the production of electrical energy, and reusing the water vapour
for district heating, greenhouse cultivation and
thermal bathing. The average geothermal gradient is 30° per
kilometre of depth, although the value varies
enormously from zone to zone.
Geothermal system
This is a reserve within the planet where it is economically
advantageous to extract heat by exploiting the principle of fluid convection,
which tends to carry heat towards the surface. A
geothermal system consists of three elements: a heat source
(rocks in a solid or molten state at a temperature generally
above 600°); a reservoir; and a fluid (generally consisting of
water). The last two elements can be of natural
or artificial origin.
Classification of geothermal systems
A first distinction between geothermal systems separates true
geothermal plants — large in scale, associated with
a high quantity of energy used, and linked to
internal temperatures of 600° and above — from
micro-geothermal systems, which exploit the difference in degrees centigrade at
low depths from the surface and the temperature stability
relative to the outside, in the context of domestic heating and
cooling. Within classical geothermal energy
we distinguish:
– Vapour-dominated systems: the fluid exists in a vapour state
and is associated with high pressures.
– Water-dominated systems: the temperature of the liquid is
at least 60° and can exceed 100.
These 2 systems, also known as thermal systems, are generally fed by
a magmatic source and are the most widely used in
commercial settings for the production of electrical energy. The flow of
steam coming from underground produces a force sufficient to drive
a turbine; the mechanical energy of the turbine is then
converted into electricity by means of an
alternator system.
– Geopressurised systems: still little exploited commercially,
these are true basins "trapped" in permeable rocks at
considerable depths (3–7 km). Experiments aimed at their
use have been developed in the Gulf of Mexico.
– Hot dry rock systems: in this type, hot rocks in the subsoil are exploited by compensating for the lack of fluid,
which is injected artificially. Hot Dry Rock systems may
also involve the creation of artificial reservoirs.
– Magma: a system still far from economic maturity,
consisting of the potential exploitation of the direct heat of magma.
Experiments have been conducted since the 1980s in the Hawaiian Islands.
Geothermal exploration
Although the average geothermal gradient is 3° per 100
metres of depth, the real geothermal potential
of a site must be verified before any possible actual use, and
only a few sites are suitable for classical geothermal power plants
combined with electricity production and widespread
heat exploitation. The main limitation of
geothermal energy is precisely that it must be confined
to zones where deposits with sufficient
thermal potential are present. A further difficulty is posed by the costs
of site analysis. Identification of a site and its potential
can only be verified through drilling
into the crust, an operation that is very costly and complex. To reduce
costs, a series of preliminary surveys is carried out. Before
actual well drilling and subsequent exploitation of a
site, geological and hydrogeological studies are conducted, along with geochemical and geophysical surveys, which allow deposits
and their characteristics to be identified. The case of
micro-geothermal energy is different: it allows the direct use of heat and
makes it possible to exploit even modest temperature differences
between the external atmosphere and the shallow depths
at which the pipework is installed, in a domestic setting.
The Lindal diagram (1973) divides geothermal sources in
relation to their temperatures and therefore according to the commercial
exploitation obtainable. Electricity production
is the most important form of utilisation of
high-temperature geothermal resources (›150°C). At
lower temperatures, in addition to direct heat use,
thermal bathing, food industry applications, heat pumps
and aquaculture may be considered.
Among the possible classifications of geothermal resources,
we distinguish those of high, medium and low enthalpy. Enthalpy,
similar to temperature, expresses the thermal content of fluids.
Water-dominated or vapour-dominated thermal systems are high-enthalpy systems, associated with the production of large quantities of
energy.
Electricity production
Electrical energy is produced in conventional or binary-cycle plants according to the characteristics of the available geothermal reserves.
Conventional plants require fluids with a
temperature of at least 150° and are available in the back-pressure type
(with direct discharge into the atmosphere — simpler
and less costly) and in the condensing type. The steam may
come directly from the wells or is separated from the liquid portion
if the wells produce wet steam. In the first case it passes
through the turbine and is then released into the atmosphere; in the
second case the steam, once it has driven the turbine and been condensed,
is re-injected into the reservoir to be used again,
creating a closed system with less waste and lower
fluid consumption. These systems, generally more complex,
have greater outputs than back-pressure systems, generally ranging
between 50 and 100 MW. The considerable advances recorded in
recent decades in binary-cycle technology have made
it possible to produce electricity using medium-to-low-temperature geothermal fluids.
In the 1990s a new binary system was tested — the Kalina cycle, which
uses a mixture of water and ammonia as the working fluid.
Such plants appear to have a higher efficiency than conventional binary plants, but compared with the latter they have greater
construction and operational complexity.
Direct use of heat
The direct use of heat is the oldest, most versatile and most common form of geothermal energy exploitation. Balneology, district and space heating, agricultural uses, aquaculture and certain industrial applications are the best-known uses, but heat pumps are the most widespread form of use. Space and district heating have undergone major development in Iceland, where geothermal heating systems are operational with a capacity of 1,200 MW; but this form of use is also very widespread in Eastern Europe, the United States, China, Japan and France. Geothermal heating of residential districts requires a substantial capital investment. The greatest costs are the initial ones for production and reinjection wells, the costs of downhole and distribution pumps, pipelines and distribution networks, monitoring and control instrumentation, supplementary plant for peak periods and buffer (reserve) storage tanks. Compared with conventional systems, however, operating costs are lower. In regions where the climate allows, economic benefits can be gained by combining space heating and cooling systems. Space cooling is achievable when absorption systems can be adapted to operate with the available geothermal fluids. They work by following a cycle that uses heat instead of electricity as an energy source. Cooling is achieved using two fluids: a refrigerant that circulates, evaporates (absorbing heat) and condenses, and a secondary or absorbent fluid.
Micro-geothermal
Space conditioning (heating and cooling) using geothermal energy has spread considerably since the 1980s, following the introduction and diffusion of heat pumps on the market. The various heat pump systems available make it possible to economically extract and use the heat contained in low-temperature bodies, such as the ground, shallow aquifers and surface water masses. Many heat pumps are reversible, being able to operate alternately as heating or cooling units.
Heat pumps require electrical energy to operate but, in suitable climatic conditions, the energy balance is positive, all the more so if the load is supplied by photovoltaic generators. Domestic uses of this kind allow heat to be produced from very low-temperature sources (low enthalpy). Within the EU, Sweden is the country with the greatest installed capacity of this type of plant (2,909 MWth) and the highest number of installations (320,687), followed by Germany (1,652.9 MWth and 150,263 installations) and France (1,366 MWth and 124,181 installations).
The sizing of the system depends on the type of end use and the volume to be heated. Pumps with a capacity of up to around 2 kW are suitable for studio flats and can also be used for domestic hot water heating. Pumps with a capacity of between 10 and 20 kW are suitable for serving multiple rooms, while those with a capacity above 20 kW are ideal for multiple apartments, offices and commercial services.
When choosing a heat pump, it is necessary to consider the climatic characteristics of the location where it is installed, the typological characteristics of the building, and the conditions of use (heating only, heating and cooling with or without domestic hot water production). Low-enthalpy or mini-geothermal systems therefore exploit the subsoil as a thermal reservoir from which to extract or transfer heat. This type of system is adaptable to any building regardless of its location. The constituent elements are: heat exchangers, heat pumps and the distribution system (preferably radiant panels and ventilation outlets). The heat exchangers are closed systems made of polyethylene, horizontal (coils) or vertical (probes), inserted into boreholes filled with cement and bentonite, through which a non-toxic heat-transfer fluid circulates, generally water plus antifreeze liquid. The temperature stability in the subsoil, even at shallow depths, and the geothermal gradient make it possible to exploit its benefits both in winter (heat) and in summer (cool).
In the case of vertical probes, the depth is generally between 100 and 300 metres depending on the composition of the ground and its thermal conductivity. The probes should be spaced, where possible, 8–10 metres apart to avoid thermal saturation phenomena.
Environmental impact and economic considerations
Energy produced from geothermal sources is a form of clean and renewable energy; it does not involve the production of climate-altering gases and is capable of regenerating itself within the human timescale (unlike non-renewable sources, fossil fuels and nuclear). Geothermal energy does not emit CO2, it is a free source (only the cost of the installation is paid for) and it is programmable, guaranteeing continuity of production that ensures a greater number of operating hours compared to other renewable sources such as wind or photovoltaic. It is nevertheless appropriate to mention the micro-pollution implications associated with the exploitation of classical geothermal energy. A slight increase in temperature near the wells is possible, and the occurrence of more frequent fog than would be present in the absence of exploitation of the source could also occur, as could phenomena of subsidence (ground sinking) and increased drought.
Construction costs for installations vary depending on the site. In all cases, the greatest investment is represented by the cost of exploration and drilling of wells. In the context of electricity production, direct costs range from $1,000 to $2,000 per kWp of installed capacity, plus indirect and maintenance costs that fluctuate between 10 and 30% of direct costs. Obviously, installations for electricity production are characterised by very substantial capacities and can therefore benefit from economies of scale that keep prices down. In this sense we distinguish between small-scale installations (<5 MW), medium-scale installations (between 5 and 30 MW) and large-scale installations (>30 MW). The economic benefit derived from these installations is not only linked to the sale of electricity on the market but also to the obtaining of Green Certificates, to the bureaucratic simplification during the construction phase from which renewable sources benefit, and to incentive mechanisms such as Net Metering (up to 200 kWp) and the All-inclusive Tariff (up to 1 MWp).
The construction cost of mini-geothermal installations, which varies depending on the characteristics of the site, can be approximated to a value of between €40 and €100 per linear metre of depth. Based on the characteristics of the ground, we can estimate the extractable power per metre (for example, 50 Wp). If we therefore wished to build a 16 kWp installation, to find out the required length of the probes it is simply a matter of doing the calculation 16,000/50 = 320 linear metres, which can be divided into 3 probes of 106 metres each. The construction cost of a similar installation (approximately €28,000) may be considerably higher than a conventional installation, but it implies virtually zero running costs with significant savings in terms of fuel used: €2,500 if natural gas and up to €4,000 if diesel or LPG. This results in very short payback periods of between 5 and 8 years, against an average installation lifespan of at least 20 years.